Description:AIV’s Bellow Condensate Collection Pipe Manifolds integrates steam traps, pipe manifolds, valves and other components. Standardized components and centralized location simplifies installation and fundamentally saves costs. Daily maintenance is more convenient, and it is equipped with AIV bellows globe valve and steam trap, with reliable quality assurance.
Application: High-pressure chemical pipelines and pipeline heating.
Advantage:
1. Integrated design and rugged construction can shortens construction time on site, minimizes installation space and easy to maintain.
2. Integral ball plug sealing surface and Stellite alloy hardened seat ensure perfect sealing.
3. Stainless steel bellows design for easy to operate,durable, and eliminates leakage at the packing.
Main part materials
Special Reminder:
1. The bellows globe valves should be fully open or fully closed during operation, and cannot be used as a throttling function!
2. Reject the use of torque wrench to close the valve to prevent excessive torsion to damage the bellows!
3. The installation is recommended to have condensate outlet at the top and shut-off valve at the bottom for drainage.
Application: High-pressure chemical pipelines and pipeline heating.
Advantage:
1. Integrated design and rugged construction can shortens construction time on site, minimizes installation space and easy to maintain.
2. Integral ball plug sealing surface and Stellite alloy hardened seat ensure perfect sealing.
3. Stainless steel bellows design for easy to operate,durable, and eliminates leakage at the packing.
Main part materials
Pipe Manifolds Body |
CF8,A105 |
Bonnet |
CF8,A105 |
Bellows assembly |
SS304 |
Stem |
SS304 |
Plug |
SS440C |
Hand Wheel |
SS304 |
Seal Gasket |
Flexible Graphite |
Special Reminder:
1. The bellows globe valves should be fully open or fully closed during operation, and cannot be used as a throttling function!
2. Reject the use of torque wrench to close the valve to prevent excessive torsion to damage the bellows!
3. The installation is recommended to have condensate outlet at the top and shut-off valve at the bottom for drainage.